SLC21/WK6: Electricity bill and Electrical Cable, Circuit Breaker size Calculation!

in hive-180106 •  yesterday 
SLC21_WK6_ Electricity bill and Electrical Cable, Circuit Breaker size Calc_20241203_182314_0000.png
Thumbnail image design by canva app

Another interesting week. I learned a lot from your courses, which were six weeks long. So I thank you both Professors @solaymann and @mahadisalim who arranged this course. And tried to explain electrical engineering concepts in a very simple way.

Even if one is not an electrical engineering student, he / she can easily understand these concepts. Unfortunately, I could not participate in all your courses. I have only participated in one course before.

So there were my papers. That's why I didn't participate. So I learned about this course and made a post, so I request my steemit team that you give another chance to both professors and Steemian learn about various concepts which is related to the field of electrical.

I pray to Allah that Allah may always keep you safe and give you success in every field.

C3TZR1g81UNaPs7vzNXHueW5ZM76DSHWEY7onmfLxcK2iQCF9KzCVqC7H7TqpFwxz9THg4DTwbKDjJvZL5DmXRXgfF3gZokZFLZt3NQw1csg1u5xfJ9YVeW.png

Write three key differences between XLPE and PVC cables?

DifferenceCross-linked Polyethylene (XLPE) CablePolyvinyl Chloride (PVC) Cable
ConnectionXLPE cables are used for electrical connection of line above 33KV.PVC Cables are used for electrical connection of line up to maximum 11KV.
DurabilityThe durability of this cable is high.The durability of this cable is short as compared to XLPE.
CostExpensive as compared to PVC cablesCheaper as compared to XLPE cables
TemperatureTemperature resistance of this cable up to 90 degrees CelsiusTemperature up to 70 degrees Celsius
Usage / VoltageXLPE cables are used in high voltage linesPVC cables are used in low voltage lines

C3TZR1g81UNaPs7vzNXHueW5ZM76DSHWEY7onmfLxcK2iQCF9KzCVqC7H7TqpFwxz9THg4DTwbKDjJvZL5DmXRXgfF3gZokZFLZt3NQw1csg1u5xfJ9YVeW.png

Write three key differences between single-core, two-core, and three-core cables?
DifferenceSingle-coreTwo-coreThree-core
UsageSingle core cables are used in Electrical connection for homeThese are used in home applianceThese are used in three phase motor
ConnectionLoads are connected through single wireLoads are connected through two wiresLoads are connected through three wires i-e (Red, yellow, black or green)
SizeThe size of single core cables up to (1-500) RM and these are used in low voltageThe size of two core cables up to 220 VThe size of three core cables up to (1-300) RM and are also used in low voltage

C3TZR1g81UNaPs7vzNXHueW5ZM76DSHWEY7onmfLxcK2iQCF9KzCVqC7H7TqpFwxz9THg4DTwbKDjJvZL5DmXRXgfF3gZokZFLZt3NQw1csg1u5xfJ9YVeW.png

Write about peak and off-peak hours in your country?
Peak & Off-peak hour

I clearly understand the concept of peak and off peak hours. Earlier I didn't know about these concepts because I'm student of law.

You explained to us about these concepts in a very easy way.

According to Official website of FESCO the peak and off-peak hours are below:

MonthsPeak HoursOff-peak Hours
December to February5 PM to 9 PMRemaining 20 Hours
March to May6 PM to 10 PMRemaining 20 Hours
June to August7 PM to 11 PMRemaining 20 Hours
September to November6 PM to 10 PMRemaining 20 Hours

C3TZR1g81UNaPs7vzNXHueW5ZM76DSHWEY7onmfLxcK2iQCF9KzCVqC7H7TqpFwxz9THg4DTwbKDjJvZL5DmXRXgfF3gZokZFLZt3NQw1csg1u5xfJ9YVeW.png

B. Calculate your house load and prepare the electricity bill for November 2024 by following Example 1?
  • In my house, four lights of 12 watts are on for 6 hours per day

  • Five fans of 62 watts (size 48 inches)are on for 4 hours per day

  • Refrigerator of 4k watts is on for 1 hour per day due to change in season because winter has arrived.

  • Our electricity company's (FESCO) electricity bill per unit is 0.14 Steem / 11.7 PKR.

Solution
Account to Formula

Electricity consumption= Watt × Number Of Loads × Hours

1KW = 1000W

C3TZR1g81UNaPs7vzNXHueW5ZM76DSHWEY7onmfLxcK2iQCF9KzCVqC7H7TqpFwxz9THg4DTwbKDjJvZL5DmXRXgfF3gZokZFLZt3NQw1csg1u5xfJ9YVeW.png

Calculate the Electricity consumption of Lights / Lamps

Electricity consumption of Lights/ Lamps per day= Watts × Number Of Loads × Hours

= 12 × 4 × 6

= 288 WH =0.288 KWH

C3TZR1g81UNaPs7vzNXHueW5ZM76DSHWEY7onmfLxcK2iQCF9KzCVqC7H7TqpFwxz9THg4DTwbKDjJvZL5DmXRXgfF3gZokZFLZt3NQw1csg1u5xfJ9YVeW.png

Calculate the Electricity consumption of Fans

Electricity consumption of Fans per day= Watts × Number Of Loads × Hours

= 62 × 5 × 4

= 1240 WH =1.24KWH

C3TZR1g81UNaPs7vzNXHueW5ZM76DSHWEY7onmfLxcK2iQCF9KzCVqC7H7TqpFwxz9THg4DTwbKDjJvZL5DmXRXgfF3gZokZFLZt3NQw1csg1u5xfJ9YVeW.png

Calculate the Electricity consumption for Refrigerator

Electricity consumption for Refrigerator per day= Watts × Number Of Loads × Hours

=4,000 × 1 × 1

= 4,000 WH = 4KWH

Total Electricity consumption in a day

Lights/ Lamps + Fans + Refrigerator

=(0.288+1.24+4)KWH

=5.52 KWH

1KWH = 1Unit

5.52 unit consume per day.

C3TZR1g81UNaPs7vzNXHueW5ZM76DSHWEY7onmfLxcK2iQCF9KzCVqC7H7TqpFwxz9THg4DTwbKDjJvZL5DmXRXgfF3gZokZFLZt3NQw1csg1u5xfJ9YVeW.png

Total Electricity consumption for November 2024

|Using Formula = Total Electricity consumption in a day × 30

=5.52 × 30

= 165.6KWH

165.6 units

Electricity bill per unit = 0.14 steem
Total Electricity consumption bill for November 2024 = Total Electricity consumption for November 2024 × Per unit cost

= 165.6 × 0.14

= 23.184 steem

C3TZR1g81UNaPs7vzNXHueW5ZM76DSHWEY7onmfLxcK2iQCF9KzCVqC7H7TqpFwxz9THg4DTwbKDjJvZL5DmXRXgfF3gZokZFLZt3NQw1csg1u5xfJ9YVeW.png

C. Calculate the total electricity bill with the HT meter values ​​given in Example 2 and design an electricity bill in Excel?

Peak Rate 1.5 steem

Off peak Rate 1.0steem


Formula

R1 (Peak) = (2665.26-2625.20) × 18,000 = ?

= (40.06) × 18,000

= 7,21,080 KWH

R2 (Off Peak) = (9825.21-9692.81) × 18,000 = ?

= (133) × 18,000

= 2,394,000 KWH

Total KWH = R1 + R2 = ?

R1 = 7,21,080 KWH

R2 = 2,394,000 KWH

= 7,21,080 + 2,394,000

= 3,115,080

TOTAL KWH = (12490.47-12318.01) = R1 + R2

= 172.46 = 3,115,080

Total Electricity Consumption Bill= R1 (Peak) × 0.15 = ?

= 7,21,080 × 0.15

= 108,162

Total Electricity Consumption Bill= R2 (Off Peak) × 0.10 = ?

= 2,394,000 × 0.10

= 2,39,400

C3TZR1g81UNaPs7vzNXHueW5ZM76DSHWEY7onmfLxcK2iQCF9KzCVqC7H7TqpFwxz9THg4DTwbKDjJvZL5DmXRXgfF3gZokZFLZt3NQw1csg1u5xfJ9YVeW.png

Sorry 😔 professors I don't know the use of Excel sheet to generate bill. It is very difficult task for me. So due to this reason I don't generate the bill. I apologize to you.

C3TZR1g81UNaPs7vzNXHueW5ZM76DSHWEY7onmfLxcK2iQCF9KzCVqC7H7TqpFwxz9THg4DTwbKDjJvZL5DmXRXgfF3gZokZFLZt3NQw1csg1u5xfJ9YVeW.png

D. Figure out the cable and circuit breaker sizes you need to setup a 20 ampere, 220 volts, and power factor (PF) 0.9 washing machine at home?

V = Voltage = 220 volts

I = Current = 20 Amp

PF = Power factor = 0.9

Power = P = ?

P = V × I × PF

P = 220 × 20 × 0.9

P = 3960 W

According to Instructor Instructions mentioned in course

So we dividing the answer of power (3960) by three

= 3960/3

= 1320 W

From my answer I clearly know that 1320 Watt load would require a 2.0 RM cable size mentioned in above figure in course and C10 (10 Amp) circuit breaker for that electrical home appliance load.

C3TZR1g81UNaPs7vzNXHueW5ZM76DSHWEY7onmfLxcK2iQCF9KzCVqC7H7TqpFwxz9THg4DTwbKDjJvZL5DmXRXgfF3gZokZFLZt3NQw1csg1u5xfJ9YVeW.png

I invited to my friends to participate in this amazing contest

@aaliarubab, @wuddi and @missyleo

Best Wishes 😍 Always be happy

Zdu5KT4nsY5HP185sqBTztTg7PEuFMMNpnMxbogYFz3GxRozjyHU9YpcD8TERPkxq5xF6TPjktb3YdPED1Cp4WAZJH4SUfkxsLgY7HtJwX...717jy9kU2HtpZVS5Wt17P1UaUBQbp2Js1rGQK2v2Cw7xdjqMMWi3abKXyJ4Z1Tz7qZ6P2dcLuThgGwSFEPryAQF5aywD4sFbNsAi2RUR45VzsRfQDDNgJKCjWu.gif

C3TZR1g81UNaPs7vzNXHueW5ZM76DSHWEY7onmfLxcK2iQCF9KzCVqC7H7TqpFwxz9THg4DTwbKDjJvZL5DmXRXgfF3gZokZFLZt3NQw1csg1u5xfJ9YVeW.png