Awesome images and writeup! (I will admit I haven't fully read through it but plan to once I'm finished with this work). I had a lot of fun using microwave magnets on a 20kV, low-vacuum plasma stream last year, as you could get a significant bend without getting too close to the high voltage output.
RE: Capturing Plasma in Magnetic Fields & Updated Hardware
You are viewing a single comment's thread from:
Capturing Plasma in Magnetic Fields & Updated Hardware
I am planning on using Microwave Oven Transformers to construct a Plasma Electrode electron gun as one of my upcoming projects!
Downvoting a post can decrease pending rewards and make it less visible. Common reasons:
Submit
I'm curious, why the oven transformer? I've typically avoided those because of the low voltage/high current. I guess lower voltage might be better in this case since that won't produce any escaping xrays.
Downvoting a post can decrease pending rewards and make it less visible. Common reasons:
Submit
I will dedicate an entire article to this shortly after I get a few more flanges and components. The short version is that the electron beam current has relation (i think its linear-ish) to both the applied voltage and current. The higher the applied plasma current, the higher the electron beam current. To somewhat meet in the middle, my plan is to put two or three MOTs in series with each other so the output is around 1/2 amp at 4-6 kV. This should supply me with an electron beam current comparable to the input current. I will then use the HV supply that I used for this article to provide the accelerating voltage for the electron beam.
As for the Xrays, I am fairly safe because I keep a geiger counter on me and have only picked them up once. In addition, the majority of radiation generated from electron impacts are at the characteristic excitation frequencies of that metal. One nice quality about these characteristic frequencies is that they are also readily absorbed/blocked by the same material. So as long as the electrons are striking steel, the majority of the radiation generated will not get past the walls of the chamber. However, it could go through the viewport but, due to emission angles, the amount that gets through is typically very small. Here is an image that illustrates the K Alpha & Beta bands for copper radiation. These are the characteristic radiation emissions for copper, which are also readily absorbed by copper. This is the source for the image: http://ruby.colorado.edu/~smyth/G30105.html
I may end up using the electron beam to make either an X-ray Fluoresce element analyzer or an electron beam welder (Hell, why not both!).
Downvoting a post can decrease pending rewards and make it less visible. Common reasons:
Submit